Home / Waste disposal / INCECO Biomedical Waste Incinerator

01 • Waste disposal • Biomedical waste

Smokeless biomedical waste incinerator

INCECO treats infectious biomedical waste on site at hospitals, PHCs and laboratories. Twin electrically heated chambers and a multi-stage flue-gas train are designed to meet the Bio-Medical Waste Management Rules, 2016.

Twin electrically heated chambersSecondary chamber ~1050 °C5–7 kg to 45–50 kg per batchIndependently stack-tested
INCECO biomedical waste incinerator by Stree Sanman
Hospital worker placing sealed biomedical waste bags into a covered bin

The challenge

Infectious waste is a daily risk for every hospital

1
Storage and transport riskWaste waiting for pickup exposes nurses, patients and sanitation workers to infection.
2
Dumping and open burningWhere collection is irregular, medical waste ends up burned or dumped near communities.
3
Compliance pressureFacilities must meet the BMW Rules, 2016 and Kayakalp standards for waste handling.

Our answer: INCECO destroys incinerable waste on site, the same day, with a cleaned, smokeless exhaust.

VJTIPerformance
certified
Sept 2026

Independently certified

VJTI Mumbai certifies INCECO for biomedical waste

An independent third-party performance evaluation, thermal efficiency audit and emission test by VJTI found INCECO compliant with the Bio-Medical Waste Management Rules, 2016, with stack emissions far below CPCB limits.

99.8%Particulate matter removed0.68 mg/Nm³ at stack vs CPCB limit 50
BDLDioxins & furansBelow detection limit; CPCB limit 0.1 ng TEQ/Nm³
No visible smokeAt the stack outletRingelmann 0
99.7%Combustion efficiencyRequirement: at least 99%
1,055°CSecondary chamber2.15 s gas residence time
95–98%SO₂, NOx, CO, HCl reducedBy the four-stage pollution control device
94.5%Waste mass reduction20 kg batch reduced to about 1 kg ash
0Fuel used
SWM Rules 2016, Schedule II-CBMW Rules 2016, Schedule IICPCB Sanitary Waste Guidelines 2018
Request the full VJTI reportFill in the enquiry form and choose “VJTI Test Report” under service. Our team will share it with you.
Recommended for final acceptance and deployment for on-site disposal.Independent third-party evaluation by the Civil & Environmental Engineering Dept., VJTI Mumbai · Report CEED/CON/4070/2026 · Tested at Thane Civil Hospital and Central Hospital, Ulhasnagar

Why choose it

Key benefits

Treat waste where it is generated

Infectious waste is destroyed on site, cutting storage time, handling and transport risk for your staff and the community.

Built for BMW compliance

The secondary chamber reaches about 1050 °C, the temperature prescribed for biomedical waste, before gases pass through the cleaning train.

Smokeless operation

A water scrubber, activated carbon and our patented corona-discharge smoke absorption unit clean the exhaust before release.

Sized to your facility

Batch models from 5–7 kg for PHCs and clinics up to 45–50 kg (INCECO-M) for district and civil hospitals.

How it works

From infectious waste to clean exhaust

Waste is burned in two stages at controlled temperatures, then the flue gas is cleaned in three further stages.

Waste loadingyellow-category BMW
Primary chamber~800 °C
Secondary chamber~1050 °C
Water scrubberacid gases, particulates
Activated carbonorganics, odour
Corona dischargepatented smoke absorption
Clean exhaustmonitored

Ideal for

Where it is used

Government hospitalsDistrict and civil hospitalsPrimary health centresRural and sub-district hospitalsMedical collegesPathology and research labsVeterinary hospitalsNursing homes and clinics

Installed at

  • Thane Civil Hospital
  • Central Hospital, Ulhasnagar
  • Karjat Sub-District Hospital
  • 12 primary health centres in Raigad district
View full technical specifications
TechnologyTwin-chamber, electrically heated smokeless incinerator
Primary chamberAbout 800 °C
Secondary chamberAbout 1050 °C for biomedical waste
Flue-gas treatmentWater scrubber, activated carbon and patented corona-discharge smoke absorption unit
Models5–7 kg per batch; 20–25 kg per batch; INCECO-M 45–50 kg per batch
Waste handledIncinerable biomedical waste as defined in the BMW Rules, 2016
Regulatory basisDesigned to the Bio-Medical Waste Management Rules, 2016
Independent testingStack tests on 12 units at Raigad-district PHCs (2022); Performance, thermal efficiency and emission evaluation certified by VJTI Mumbai (Report CEED/CON/4070/2026, September 2026)

Electrical rating, footprint and price depend on the model. Ask for the datasheet for your capacity.

See it in action

Photos and video

Impact parameters

Impact we measure and report

Every installation is tracked against clear, verifiable parameters so you can report outcomes to regulators, boards and CSR committees.

52

INCECO units installed

Across hospitals, PHCs, municipalities and institutions, all models combined.

12

PHC units stack-tested

Raigad-district units tested in 2022 were within prescribed limits, with dioxins and heavy metals not detected.

Waste treated on site

Kilograms of biomedical waste destroyed per day and per month, logged per batch.

Emissions and temperature

Stack parameters and chamber temperatures recorded so you can show compliance at inspection.

Policy & SDG alignment

Aligned with national priorities and global goals

UN Sustainable Development Goals

SDG3
Good health and well-being Safe destruction of infectious waste protects patients, staff and sanitation workers.
SDG6
Clean water and sanitation Prevents untreated medical waste reaching drains, water bodies and dumps.
SDG9
Industry, innovation and infrastructure Patented, Made-in-India clean-technology for health infrastructure.
SDG12
Responsible consumption and production Supports environmentally sound management of hazardous waste (target 12.4).

Central government policy

Bio-Medical Waste Management Rules, 2016

Enables hospitals to treat incinerable waste to the temperatures and emission norms the rules prescribe.

Kayakalp (National Health Mission)

Strengthens the waste-management and infection-control scores public health facilities are assessed on.

Swachh Bharat Mission

Keeps hospital campuses and their surroundings free of open medical waste.

Prime Minister’s vision

Swachh Bharat

Clean, safe public health facilities across India.

Atmanirbhar Bharat and Make in India

Designed and manufactured in Maharashtra.

Viksit Bharat @2047

Modern, compliant health infrastructure down to the PHC level.

CSR alignment

Schedule VII (i)

Preventive health care and sanitation.

Schedule VII (iv)

Environmental sustainability and ecological balance.

Schedule VII (x)

Rural development, when deployed at rural PHCs and sub-district hospitals.

Testimonials

What our clients say

“Implementing a smokeless biomedical waste incinerator has significantly improved our community’s health and well-being. By eliminating harmful emissions, it ensures cleaner air and a safer environment for everyone.”

Vishal Wabhase
Pharmacy Officer, Thane Civil Hospital

“Switching to a smokeless biomedical waste incinerator has been a game-changer for our facility. Not only does it efficiently dispose of waste, but it also ensures a cleaner environment.”

Dr. Vijay Mhaskar
Medical Superintendent, Karjat Sub-District Hospital

Frequently asked questions

Questions about INCECO Biomedical Waste Incinerator

Which biomedical waste can INCECO treat?

INCECO is designed for incinerable biomedical waste as defined in the Bio-Medical Waste Management Rules, 2016, such as the waste streams the rules route to incineration. Our team confirms suitability for your waste mix during the site assessment.

Does INCECO meet the BMW Rules temperature requirements?

Yes. The primary chamber operates at about 800 °C and the secondary chamber at about 1050 °C, the temperature range prescribed for biomedical waste incineration, followed by a scrubber, activated carbon and a corona-discharge unit.

Which capacity should our hospital choose?

PHCs and clinics typically choose the 5–7 kg per batch model, mid-sized hospitals the 20–25 kg model, and district or civil hospitals the 45–50 kg INCECO-M. We size the unit from your daily waste generation.

Has INCECO been independently tested?

Stack tests on 12 INCECO units at Raigad-district PHCs in 2022 were within prescribed limits, with dioxins and heavy metals not detected. VJTI Mumbai is carrying out an independent performance and emission evaluation.

Can a BMW incinerator be funded through CSR?

Yes. Installing incinerators at government hospitals and PHCs qualifies under Schedule VII of the Companies Act (health care and sanitation, and environmental sustainability). We prepare CSR-ready proposals for funders.

Get a proposal

Get a proposal for your hospital

Share your daily biomedical waste quantity and location. Our engineers will recommend the right INCECO model and send a proposal within one working day.

  • ✓ Free site and requirement assessment
  • ✓ Recommended model and capacity
  • ✓ Compliance and documentation support
  • ✓ CSR and government funding guidance